Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cornea ; 40(5): 628-634, 2021 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-33156081

RESUMO

PURPOSE: To evaluate the long-term results of combining cataract surgery, intraocular lens (IOL) implantation, and Descemet membrane endothelial keratoplasty with peripheral stromal support (DMEK-S). METHODS: The outcomes of 107 eyes of 37 patients who had undergone a combination of cataract surgery, IOL implantation, and DMEK-S between October 2007 and February 2015 were retrospectively evaluated. The average follow-up duration was 18.2 ± 18.3 months (range, 6-84 months). Changes in uncorrected and corrected distance visual acuity, spherical equivalent, and corneal endothelial cell density were analyzed. Intraoperative and postoperative complications were also recorded. RESULTS: The mean logMAR uncorrected distance visual acuity improved from 0.92 ± 0.60 preoperatively to 0.33 ± 0.33, 0.28 ± 0.25, 0.24 ± 0.20, and 0.27 ± 0.27 at 6, 12, 24, and 36 months postoperatively (P < 0.001), respectively. The mean logMAR corrected distance visual acuity improved from 0.62 ± 0.65 preoperatively to 0.17 ± 0.29, 0.13 ± 0.21, 0.07 ± 0.16, and 0.11 ± 0.23 at 6, 12, 24, and 36 months postoperatively (P < 0.001), respectively. The mean endothelial cell density decreases were 50.7% ± 21.1%, 50.8% ± 19.8%, 60.7% ± 16.6%, 62.2% ± 11.8%, and 61.8% ± 20.0% at 6, 12, 24, 36, and 48 months after surgery, respectively. Similar trends, although with slightly better visual outcomes, were found in the subgroup of patients without other eye diseases. The mean final deviation from intended spherical equivalent was 0.77 ± 1.19 D, representing a hyperopic shift. CONCLUSIONS: A combined procedure of cataract surgery, IOL implantation, and DMEK-S is an effective method of treatment in patients with combined corneal disease and cataract, maintaining visual rehabilitation in the long term. Future developments should be performed to minimize the incidence of complications.


Assuntos
Catarata/complicações , Doenças da Córnea/complicações , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Facoemulsificação , Idoso , Idoso de 80 Anos ou mais , Contagem de Células , Perda de Células Endoteliais da Córnea/fisiopatologia , Substância Própria/cirurgia , Endotélio Corneano/patologia , Feminino , Seguimentos , Humanos , Implante de Lente Intraocular , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Transtornos da Visão/reabilitação , Acuidade Visual/fisiologia
2.
Int Ophthalmol ; 39(12): 2875-2882, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31168677

RESUMO

PURPOSE: To compare the visual and refractive outcomes obtained with the implantation of a rotationally asymmetric refractive multifocal IOL after femtosecond laser-assisted cataract surgery (FLACS) and conventional lens extraction (CLE). METHODS: A total of 78 eyes of 58 patients that had undergone conventional phacoemulsification (36 eyes, CLE group) or FLACS (37 eyes, FLACS group) with the implantation of the toric multifocal IOL LU-313 MF30T (Oculentis, Germany) were enrolled in this retrospective study. Mean age was 57.0 years at the time of surgery, ranging from 44 to 69 years. Visual and refractive outcomes were evaluated during a 12-month follow-up. Likewise, contrast sensitivity was assessed at the end of the follow-up. RESULTS: Significant improvements were observed in both groups in uncorrected distance (UDVA) and near visual acuity (UNVA) at 1 month postoperatively (p < 0.001). Differences between groups in these parameters as well as in sphere and cylinder did not reach statistical significance during the whole follow-up (p ≥ 0.079), except for UNVA only at 12 months postoperatively (p = 0.018). Concerning corrected near visual acuity, only significant differences between groups were found preoperatively (p = 0.020). Furthermore, only a minimal but significant difference between groups was found at 12 months postoperatively in contrast sensitivity for the spatial frequency of 18 cycles/° (p = 0.029). CONCLUSIONS: The rotationally asymmetric toric multifocal IOL LU-313 MF 30T provides good visual rehabilitation for near and distance vision after presbyopic lens extraction in eyes with preexisting astigmatism, independently whether the cataract surgery is performed with the FLACS or conventional technique.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares Multifocais , Facoemulsificação , Refração Ocular , Adulto , Idoso , Sensibilidades de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Facoemulsificação/métodos , Estudos Retrospectivos , Acuidade Visual
3.
Int J Ophthalmol ; 10(10): 1528-1533, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29062771

RESUMO

AIM: To evaluate and compare the clinical outcomes with a diffractive bifocal and trifocal intraocular lens (IOL) during a 12-month follow-up. METHODS: Prospective comparative study including 75 eyes of 38 patients (44-70y) undergoing uneventful cataract surgery. Each patient was randomly assigned to one type of IOL, bifocal (35 eyes) or trifocal (40 eyes). Visual, refractive, and contrast sensitivity changes were evaluated in a 12-month follow-up. The binocular defocus curve was also measured at 12mo postoperatively. RESULTS: No statistically significant differences between groups were found in postoperative uncorrected and corrected distance visual acuities (P≥0.276). Postoperative corrected near visual acuity (33 cm) was significantly better in the trifocal group during all follow-up (P≤0.004) as well as 6-month uncorrected near (P=0.008) and distance-corrected near visual acuities (P=0.016) (33/40 cm). Significantly better uncorrected intermediate and distance corrected-intermediate visual acuity were found during all follow-up in the trifocal group (P<0.001), which was consistent with differences among groups in binocular defocus curve. Differences among groups in contrast sensitivity were minimal, being only significant at 6 months for some low to medium spatial frequencies (P≤0.006). CONCLUSION: Bifocal and trifocal diffractive IOLs are able to provide an effective visual restoration which is maintained during a 12-month follow-up, with a clear benefit of the trifocal IOL for the intermediate vision.

4.
BMC Ophthalmol ; 17(1): 105, 2017 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-28659140

RESUMO

BACKGROUND: The gold standard treatments in amblyopia are penalizing therapies, such as patching or blurring vision with atropine that are aimed at forcing the use of the amblyopic eye. However, in the last years, new therapies are being developed and validated, such as dichoptic visual training, aimed at stimulating the amblyopic eye and eliminating the interocular supression. PURPOSE: To evaluate the effect of dichoptic visual training using a virtual reality head mounted display in a sample of anisometropic amblyopic adults and to evaluate the potential usefulness of this option of treatment. METHODS: A total of 17 subjects (10 men, 7 women) with a mean age of 31.2 years (range, 17-69 year) and anisometropic amblyopia were enrolled. Best corrected visual acuity (BCVA) and stereoacuity (Stereo Randot graded circle test) changes were evaluated after 8 sessions (40 min per session) of dichoptic training with the computer game Diplopia Game (Vivid Vision) run in the Oculus Rift OC DK2 virtual reality head mounted display (Oculus VR). RESULTS: Mean BCVA in amblyopic eye improved significantly from a logMAR value of 0.58 ± 0.35 before training to a post-training value of 0.43 ± 0.38 (p < 0.01). Forty-seven percent of the participants achieved BCVA of 20/40 or better after the training as compared to 30% before the training. Mean stereoacuity changed from a value of 263.3 ± 135.1 before dichoptic training to a value of 176.7 ± 152.4 s of arc after training (p < 0.01). A total of 8 patients (47.1%) before dichoptic treatment had unmeasurable stereoacuity while this only occurred in 2 patients (11.8%) after training. CONCLUSIONS: Dichoptic training using a virtual reality head mounted display seems to be an effective option of treatment in adults with anisometropic amblyopia. Future clinical trials are needed to confirm this preliminary evidence. TRIAL REGISTRATION: Trial ID: ISRCTN62086471 . Date registered: 13/06/2017. Retrospectively registered.


Assuntos
Ambliopia/terapia , Imageamento Tridimensional , Distorção da Percepção/fisiologia , Terapia de Exposição à Realidade Virtual/métodos , Visão Binocular/fisiologia , Acuidade Visual , Adolescente , Adulto , Idoso , Ambliopia/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Privação Sensorial , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
6.
Eur J Ophthalmol ; 26(6): 612-617, 2016 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-27135090

RESUMO

PURPOSE: To investigate the low mesopic contrast sensitivity function (LMCSF) of patients implanted with different modern optical bifocal and trifocal designs of multifocal intraocular lenses (mfIOLs). METHODS: This prospective, comparative, nonrandomized consecutive case series included 180 eyes that underwent cataract surgery. Six groups of eyes were differentiated: group A, eyes with the diffractive AT LISA tri 839MP; group B, eyes with diffractive FineVision; group C, eyes with the bifocal Lentis Mplus-LS313; group D, eyes with the diffractive bifocal Acri.Lisa 366D; group E, eyes with the diffractive apodized Acrysof ReSTOR SN6AD1; group F, as the control group, implanted with a monofocal spherical intraocular lens. The LMCSF was evaluated with the OPTEC® 6500 device at 3 months postoperatively using a luminance of 3 cd/m2. RESULTS: No significant differences among groups were detected in LMCSF for the spatial frequencies of 1.5, 3.0, 6.0, and 12.0 cpd (1.5 cpd: F = 1.81, p = 0.13; 3.0 cpd: F = 1.14, p = 0.14; 6.0 cpd: F = 1.87, p = 0.11; 12.0 cpd: F = 1.26, p = 0.29), but significant differences were found among groups for the spatial frequency of 18 cpd (F = 2.62, p = 0.03). When comparing the groups in pairs, only statistically significant differences were observed between groups E and F for the spatial frequency of 18.0 cpd (t = 3.27, p = 0.03) with better values for group F. CONCLUSION: No significant differences were observed in LMCSF among the different mfIOLs studied. The third focus of trifocal IOL models did not adversely affect the LMCSF. The ReSTOR SN6AD1 showed the poorest LMCSF for the highest spatial frequency analyzed when compared with the control group.


Assuntos
Sensibilidades de Contraste/fisiologia , Implante de Lente Intraocular , Lentes Intraoculares , Visão Mesópica/fisiologia , Facoemulsificação , Pseudofacia/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Acuidade Visual/fisiologia
8.
J Cataract Refract Surg ; 42(3): 485-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27006326

RESUMO

A 71-year-old woman with Fuchs endothelial dystrophy in the right eye had uneventful phacoemulsification cataract surgery with implantation of a single-piece intraocular lens (IOL) (CT47S) in January 2012. Because of corneal problems and vision loss, uneventful Descemet-stripping automated endothelial keratoplasty (DSAEK) was performed in May 2013. Four months later, a new corneal lamella (repeat DSAEK) was implanted with reinjection of an air bubble into the anterior chamber. Six months after the initial DSAEK, the patient complained of blurred vision. On examination, the cornea was transparent but the IOL presented opacification in the central area. The opacified IOL was explanted and analyzed by light microscopy, which showed the presence of thin granular deposits distributed in an overall round pattern that stained positive for calcium. The opacification of hydrophilic acrylic IOLs is a complication that can occur after uneventful endothelial keratoplasty, especially when rebubbling is necessary.


Assuntos
Ar , Ceratoplastia Endotelial com Remoção da Lâmina Limitante Posterior , Distrofia Endotelial de Fuchs/cirurgia , Lentes Intraoculares , Falha de Prótese , Resinas Acrílicas , Idoso , Câmara Anterior/cirurgia , Calcinose/etiologia , Calcinose/patologia , Calcinose/cirurgia , Cálcio/análise , Remoção de Dispositivo , Feminino , Humanos , Interações Hidrofóbicas e Hidrofílicas , Injeções Intraoculares , Implante de Lente Intraocular , Facoemulsificação , Transtornos da Visão/etiologia , Transtornos da Visão/patologia , Transtornos da Visão/cirurgia , Acuidade Visual/fisiologia
9.
Eur J Ophthalmol ; 26(2): e24-6, 2016 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-26541107

RESUMO

PURPOSE: To describe the clinical and microscopic findings in 2 different patients of 2 cases of late opacification of the hydrophilic acrylic intraocular lens (IOL) Ioflex. METHODS: Two eyes of 2 patients (73 and 74 years old) had an uneventful phacoemulsification surgery with implantation of the Ioflex IOL (power +21.5 D). At 5 years after surgery, a dense IOL opacification was detected in both cases with significant visual degradation. The IOLs were explanted and analyzed by microscopy. RESULTS: In both cases, a satisfactory visual recovery was achieved (corrected distance visual acuity of 6/9 and 6/12). Microscopic examination of the explanted IOLs revealed multiple small granules on the surface/subsurface of the lens. Although histochemical or surface analyses were not performed, the aspect appears consistent with a process of calcification of this lens design. Other findings included few surface contaminants, such as fibers, crystals that may correspond to dry viscoelastic and/or salt solutions, as well as pigments and dust-like deposits. CONCLUSIONS: Opacification of the posterior chamber hydrophilic acrylic IOL Ioflex probably related to calcification can appear several years after its implantation and requires IOL exchange due to the significant visual loss induced. More studies are required to understand the causes of this complication.


Assuntos
Resinas Acrílicas , Lentes Intraoculares , Falha de Prótese , Idoso , Europa (Continente) , Feminino , Humanos , Interações Hidrofóbicas e Hidrofílicas , Implante de Lente Intraocular , Masculino , Facoemulsificação , Acuidade Visual
10.
J Cataract Refract Surg ; 41(8): 1623-30, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26432119

RESUMO

PURPOSE: To evaluate the visual, refractive, contrast-sensitivity, and aberrometric outcomes during a 1-year follow-up after implantation of a trifocal intraocular lens (IOL). SETTING: Premium Clinic, Teplice, Czech Republic. DESIGN: Prospective case series. METHODS: This study included eyes of patients having cataract surgery with implantation of the trifocal IOL model AT Lisa tri 839MP. Distance, intermediate (66 and 80 cm), and near (33 and 40 cm) vision; contrast sensitivity; aberrometric outcomes; and the defocus curve were evaluated during a 12-month follow-up. The level of posterior capsule opacification (PCO) was also evaluated. RESULTS: In 120 eyes (60 patients), 1 month postoperatively, an improvement was observed in all visual parameters (P ≤ .03) except corrected near and intermediate visual acuities (both P ≥ .05). From 1 month to 12 months postoperatively, small but statistically significant changes were observed in uncorrected and corrected distance and near visual acuities (all P ≤ .03) and in uncorrected intermediate visual acuity (P = .01). In the defocus curve, no significant differences were found between visual acuities corresponding to defocus levels of -1.0 diopter (D) and -2.0 D (P = .22). The level of ocular spherical aberration decreased statistically significantly at 6 months (P < .001). Ocular and internal higher-order aberrations increased minimally but significantly from 6 to 12 months postoperatively (P < .001). The mean 12-month PCO score was 0.32 ± 0.44 (SD). Four eyes (3.3%) required neodymium:YAG capsulotomy. CONCLUSION: The trifocal IOL provided complete and stable visual restoration after cataract surgery during a 12-month follow-up, with good levels of visual quality. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.


Assuntos
Sensibilidades de Contraste/fisiologia , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Aberrometria , Adulto , Idoso , Opacificação da Cápsula/diagnóstico , Aberrações de Frente de Onda da Córnea/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese
11.
J Cataract Refract Surg ; 41(12): 2695-706, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26796450

RESUMO

PURPOSE: To evaluate the visual, refractive, contrast sensitivity, and aberrometric outcomes as well as the patient quality of life and photic phenomena disturbances after cataract surgery with implantation of a new trifocal toric intraocular lens (IOL). SETTINGS: Premium Clinic, Regional Hospital in Havlickuv Brod, Czech Republic, and Vissum and Universidad Miguel Hernández, Alicante, Spain. DESIGN: Prospective consecutive series of cases. METHODS: The study involved eyes with corneal astigmatism of 1.25 D or more that were having cataract surgery with implantation of the trifocal toric IOL AT Lisa tri toric 939MP (Carl Zeiss Meditec). Visual outcomes and astigmatic changes analyzed by Alpins vector analysis were evaluated at 3 months postoperatively. Contrast sensitivity, quality of life, and photic phenomena were also evaluated. RESULTS: The study involved a total of 30 eyes of 16 patients, age 37 to 64 years. A significant improvement with surgery was observed in uncorrected distance, intermediate, and near visual acuity (P ≤ .01). A significant decrease in the refractive cylinder was observed postoperatively (P < .01), with all eyes showing a postoperative astigmatism below 1.00 D. The difference between targeted and surgically induced astigmatism was small (0.06 ± 0.30 D) but statistically significant (P = .04). The mean magnitude of angle of error was 5.80 ± 8.47 degrees. The low levels of higher-order aberrations found postoperatively were consistent with the good levels of contrast sensitivity achieved. Regarding quality of life, low to moderate levels of difficulty in performing various types of vision-related tasks were found. CONCLUSIONS: The trifocal toric IOL evaluated provides effective restoration of visual function after cataract surgery, with associated high levels of visual acuities and quality of life. FINANCIAL DISCLOSURE: The authors have no proprietary or commercial interest in the medical devices that are involved in this manuscript.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Adulto , Sensibilidades de Contraste/fisiologia , Aberrações de Frente de Onda da Córnea/fisiopatologia , Humanos , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Prospectivos , Desenho de Prótese , Qualidade de Vida , Inquéritos e Questionários
12.
J Refract Surg ; 30(10): 666-72, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25291749

RESUMO

PURPOSE: To evaluate and compare the visual, refractive, contrast sensitivity, and aberrometric outcomes with a diffractive bifocal and trifocal intraocular lens (IOL) of the same material and haptic design. METHODS: Sixty eyes of 30 patients undergoing bilateral cataract surgery were enrolled and randomly assigned to one of two groups: the bifocal group, including 30 eyes implanted with the bifocal diffractive IOL AT LISA 801 (Carl Zeiss Meditec, Jena, Germany), and the trifocal group, including eyes implanted with the trifocal diffractive IOL AT LISA tri 839 MP (Carl Zeiss Meditec). Analysis of visual and refractive outcomes, contrast sensitivity, ocular aberrations (OPD-Scan III; Nidek, Inc., Gagamori, Japan), and defocus curve were performed during a 3-month follow-up period. RESULTS: No statistically significant differences between groups were found in 3-month postoperative uncorrected and corrected distance visual acuity (P ≥ .21). However, uncorrected, corrected, and distance-corrected near and intermediate visual acuities were significantly better in the trifocal group (P < .01). No significant differences between groups were found in postoperative spherical equivalent (P = .22). In the binocular defocus curve, the visual acuity was significantly better for defocus of -0.50 to -1.50 diopters in the trifocal group (P ≤ .04) and -3.50 to -4.00 diopters in the bifocal group (P ≤ .03). No statistically significant differences were found between groups in most of the postoperative corneal, internal, and ocular aberrations (P ≤ .31), and in contrast sensitivity for most frequencies analyzed (P ≤ .15). CONCLUSIONS: Trifocal diffractive IOLs provide significantly better intermediate vision over bifocal IOLs, with equivalent postoperative levels of visual and ocular optical quality.


Assuntos
Sensibilidades de Contraste/fisiologia , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Aberrometria , Adulto , Idoso , Aberrações de Frente de Onda da Córnea/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese
13.
Eur J Ophthalmol ; 24(6): 850-6, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24846622

RESUMO

PURPOSE: To compare the safety of a single-piece, foldable intraocular lens (IOL) hydroimplantation with that of a standard implantation using an ophthalmic viscosurgical device (OVD). METHODS: One hundred consecutive patients with bilateral age-related cataract surgery were enrolled into a prospective double-blind study. Each patient's first eye was randomly assigned to a standard implantation technique with an OVD or the hydroimplantation technique, while the fellow eye received the opposite technique. The main outcomes measured were endothelial cell loss, postoperative changes of intraocular pressure (IOP), and the frequency of complications. RESULTS: The reduction of endothelial cell density 1 month and 6 months after the surgery was 9.76% ± 13.5%, 10.7% ± 12.6%, respectively, in group A (OVD) and 9.07% ± 12.7%, 9.13% ± 13.7%, respectively, in group B (hydroimplantation). The differences were not statistically significant. The mean IOP 2 hours after surgery was 10.19 ± 6.78 mm Hg in group A and 9.92 ± 7.01 mm Hg in group B. Twenty-four hours and 1 month after surgery, the mean IOP was 14.52 ± 5.59 mm Hg and 13.21 ± 3.5 mm Hg, respectively, in group A, and 15.45 ± 5.77 mm Hg and 13.1 ± 3.44 mm Hg, respectively, in group B. The differences between groups A and B were not statistically significant. CONCLUSIONS: The hydroimplantation technique is a safe technique for single-piece foldable IOL implantation. There was no increase in intraoperative and postoperative complications compared with the standard implantation technique using an OVD.


Assuntos
Pressão Intraocular/fisiologia , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Facoemulsificação/métodos , Viscossuplementação/métodos , Viscossuplementos/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Perda de Células Endoteliais da Córnea/patologia , Método Duplo-Cego , Feminino , Humanos , Complicações Intraoperatórias , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Tonometria Ocular , Acuidade Visual/fisiologia
15.
J Cataract Refract Surg ; 40(1): 60-9, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24355721

RESUMO

PURPOSE: To evaluate refractive and visual parameters related to distance, intermediate, and near vision after cataract surgery and the optical quality of a new diffractive trifocal intraocular lens (IOL). SETTING: Vissum Instituto Oftalmologico de Alicante, Alicante, Spain. DESIGN: Case series. METHODS: Patients had bilateral refractive lens exchange and multifocal diffractive IOL (AT Lisa tri 839 MP) implantation. A complete ophthalmology examination was performed preoperatively and postoperatively. The follow-up was 6 months. The main outcome measures were uncorrected distance (UDVA) and corrected distance (CDVA), intermediate, and near visual acuities; keratometry; manifest refraction; and aberrations (total, corneal, internal). RESULTS: The study comprised 60 eyes of 30 patients (mean age 57.9 years ± 7.8 [SD]; range 42 to 76 years). There was significant improvement in UDVA, uncorrected intermediate visual acuity, uncorrected near visual acuity, CDVA, and distance-corrected intermediate and near visual acuity. The postoperative refractive status was within the range of +1.00 to -1.00 diopter. Total internal aberrations decreased significantly (P<.001). CONCLUSIONS: The trifocal IOL improved near, intermediate, and distance vision in presbyopic patients. The use of 3 foci provided significant intermediate visual results without sacrificing near or distance vision.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Aberrometria , Adulto , Idoso , Sensibilidades de Contraste/fisiologia , Topografia da Córnea , Percepção de Profundidade/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Desenho de Prótese , Resultado do Tratamento
17.
Graefes Arch Clin Exp Ophthalmol ; 251(1): 341-8, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22588290

RESUMO

BACKGROUND: To evaluate the intraocular lens (IOL) position by analyzing the postoperative axis of internal astigmatism as well as the higher-order aberration (HOA) profile after cataract surgery following the implantation of a diffractive multifocal toric IOL METHODS: Prospective study including 51 eyes with corneal astigmatism of 1.25D or higher of 29 patients with ages ranging between 20 and 61 years old. All cases underwent uneventful cataract surgery with implantation of the AT LISA 909 M toric IOL (Zeiss). Visual, refractive and corneal topograpy changes were evaluated during a 12-month follow-up. In addition, the axis of internal astigmatism as well as ocular, corneal, and internal HOA (5-mm pupil) were evaluated postoperatively by means of an integrated aberrometer (OPD Scan II, Nidek). RESULTS: A significant improvement in uncorrected distance and near visual acuities (p < 0.01) was found, which was consistent with a significant correction of manifest astigmatism (p < 0.01). No significant changes were observed in corneal astigmatism (p = 0.32). With regard to IOL alignment, the difference between the axes of postoperative internal and preoperative corneal astigmatisms was close to perpendicularity (12 months, 87.16° ± 7.14), without significant changes during the first 6 months (p ≥ 0.46). Small but significant changes were detected afterwards (p = 0.01). Additionally, this angular difference correlated with the postoperative magnitude of manifest cylinder (r = 0.31, p = 0.03). Minimal contribution of intraocular optics to the global magnitude of HOA was observed. CONCLUSIONS: The diffractive multifocal toric IOL evaluated is able to provide a predictable astigmatic correction with apparent excellent levels of optical quality during the first year after implantation.


Assuntos
Astigmatismo/diagnóstico , Aberrações de Frente de Onda da Córnea/diagnóstico , Implante de Lente Intraocular , Lentes Intraoculares , Facoemulsificação , Aberrometria , Adulto , Astigmatismo/cirurgia , Topografia da Córnea , Aberrações de Frente de Onda da Córnea/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Pseudofacia/fisiopatologia , Refração Ocular/fisiologia , Acuidade Visual/fisiologia , Adulto Jovem
18.
J Refract Surg ; 27(9): 648-57, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21598872

RESUMO

PURPOSE: To analyze and compare the clinical outcomes obtained after cataract surgery with the implantation of a new multifocal toric intraocular lens (IOL) using two different types of corneal incision. METHODS: Retrospective study including 64 eyes of 35 patients who underwent surgery with implantation of the AT LISA 909M multifocal toric IOL (Carl Zeiss Meditec) in 2 different ophthalmologic centers using different criteria for corneal incision size: sub-1.8 mm (micro-incision surgery [MICS] group) and 2.2 mm (mini-incision group). Visual, refractive, and corneal topographic outcomes were evaluated during 6-month follow-up. Additionally, refractive astigmatic changes were analyzed using the Alpins vectorial method. RESULTS: Significant reductions of refractive sphere and cylinder were observed postoperatively (P<.03), with associated visual improvements for near and distance (P<.01) in both groups. Mean postoperative magnitudes of difference vector, torque, and magnitude of error in the overall sample were 0.52±0.36 diopters (D), 0.36 ± 0.36 D, and 0.08 ± 0.38 D, respectively. A mean overcorrection of 4% in refractive astigmatism was found. Mean angle of error was 0.37± 5.50° and -4.51±13.16° for the MICS and mini-incision groups, respectively (P=.09). Significant positive correlations were found between the magnitudes of torque and difference vector (r=0.78, P<.01) as well as between the magnitude of torque and absolute angle of error (r=0.76, P<.01). CONCLUSIONS: Implantation of the AT LISA toric IOL using corneal incisions <2.2 mm provides excellent predictability for astigmatic correction.


Assuntos
Córnea/cirurgia , Implante de Lente Intraocular , Lentes Intraoculares , Microcirurgia/métodos , Facoemulsificação/métodos , Adulto , Astigmatismo/fisiopatologia , Topografia da Córnea , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Refração Ocular/fisiologia , Estudos Retrospectivos , Resultado do Tratamento , Acuidade Visual/fisiologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...